How to use a hydraulic shearing machine: lower the upper blade carrier to bottom dead centre and switch off power before replacing pipe seals. Loosen the leaking fitting, remove the damaged seal, apply grease in the groove and install the new seal. If the machine develops no working pressure, check motor and pump rotation, clean the safety relief valve spool and the two-position four-way solenoid valve. If the blade carrier returns slowly, refill with oil, check connections for leakage, and check the accumulator nitrogen pressure (normally 4–5 MPa). To flip the blades, set the shear angle to zero, remove the guide plate, take out upper and lower blades in order, flip and refit them, then check that joints are smooth. Adjust blade clearance by setting an overlap of 3–5 mm at both ends, refill with oil and return to the cutting position.