Four-column presses use relief valves and directional valves to manage overload and reversing. When pressure exceeds the set value, the relief valve opens; the directional valve then changes the oil path for the return stroke. Faults may appear as pressure that will not build, slow return or sudden pressure drops. Clean oil and regular valve inspection prevent most issues.